TABLE OF ZONES
Zone No. Trigger type Input description
1 Instant H1/7 BLACK/WHITE - Connect to optional hood/trunk
pins.
2 On-board shock sensor Heavy impact detected by the on-board shock sensor.
3 Two-stage, progresses from Door switch circuit. H1/8 WHITE or H1/6 PURPLE
warning to full alarm
4 Multiplexed Input BLUE and GREEN wires of optional sensor plug. Inputs
shorter than 0.8 seconds will trigger a Warn Away
response, while inputs longer than 0.8 seconds will
instantly trigger a full alarm sequence and report Zone
4.
5 Two-stage (similar to doors) Ignition input. H1/4 ORANGE.
The Warn Away® response does not report on the LED.
LONG TERM EVENT HISTORY
The system stores the last two full triggers in memory. These are not erasable. Each time the unit sees a full trigger, the
older of the two triggers in memory will be replaced by the new trigger. To access long term event history:
1. With the ignition off, press and HOLD the Valet/Program switch.
2. Turn on the ignition.
3. Release the Valet/Program switch.
4. Press and release the Valet/Program switch within 5 seconds. The LED will flash in
groups indicating the last two zones that triggered the unit. The LED will flash for one
minute or until the ignition is turned off.
The Warning Zone triggers are not stored to memory and will not be reported.
Multi-Level Security Arming
Multi-Level Security arming allows the operator to select which inputs and sensors are active during a particular arming
cycle. For a full description of Multi-Level Security Arming operation for testing purposes refer to the owner's manual.
Optional Vehicle Recovery System (VRS
®
)
VRS
®
is an optional feature designed to disable a vehicle during a carjacking event. It must be programmed in the
features menu and the Failsafe Starter Kill must be installed for it to work properly. For operational instructions when
testing VRS
®
refer to the owner's manual.